When queried, the largest value that can be returned is 32767. This is because
the most-significant register bit cannot be set true.
Syntax
: S TAT u s : O P E R a t i o n : N T R a n s i t i o n < i n t _ v a l u e >
: S TAT u s : O P E R a t i o n : N T R a n s i t i o n ?
Example
OUTPUT 720;":STATUS:OPER:NTRansition 16"
:STATus:OPERation:PTRansition
Selects bits in the event register which can be set by positive transitions of the
corresponding bits in the condition register.
Changes in the state of a condition register bit causes the associated OPERa-
tion Status or QUEStionable Status event register bit to be set. This command
allows you to select a positive bit transition to trigger an event to be recog-
nized. A positive transition is defined to occur whenever the selected bit
changes states from a 0 to a 1. You can enter any value from 0 to 65535.
When queried, the largest value that can be returned is 32767. This is because
the most-significant register bit cannot be set true.
Syntax
: S TAT u s : O P E R a t i o n : PT R a n s i t i o n < i n t _ v a l u e >
: S TAT u s : O P E R a t i o n : PT R a n s i t i o n ?
Example
OUTPUT 720;":STATUS:OPER:PTRansition 16"
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Programming Commands
STATus Subsystem Commands
6-93