Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Measuring Instruments
86082A
Agilent Technologies 86082A Manuals
Manuals and User Guides for Agilent Technologies 86082A. We have
1
Agilent Technologies 86082A manual available for free PDF download: User Manual
Agilent Technologies
86082A
User Manual
Agilent Technologies 86082A User Manual (470 pages)
Wavelength Domain Component Analyzer
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 4.26 MB
Table of Contents
Table of Contents
6
1 Getting Started
13
Product Overview
13
Standard Product, Options, and Accessories
15
AC Line-Power Cords
18
Front-Panel Fiber-Optic Adapters
20
Agilent 86082A Front and Rear Panels
21
WDCA Display
24
Accessing the WDCA Functions
26
The Menu Bar
27
The Softkey Panels
29
The Amplitude Menus
30
The Markers Menus
31
The Normalization Reference Menu
33
The Save/Recall Menus
34
The Sweep Menu
35
The System Menus
37
The Traces Menus
39
The Wavelength Menu
41
Laser Safety Considerations
42
Setting up the WDCA
43
To Learn more about Agilent Products
48
2 Function Reference
50
3 Using the Analyzer
120
The Basics
121
To Fill in a Setup Panel
121
Adding a Title to the Display
122
Backing up or Restoring the Internal Memory
123
Moving the Active Function Area
123
Saving Measurement and Trace Data
124
Entering a Filename Using the Arrow Keys
126
Entering a Filename Using an External Keyboard
126
Saving Data in Fast Meas Save Mode
126
Recalling Measurement and Trace Data
127
Recalling Data in Fast Meas Recall Mode
128
Measurement Techniques
129
Normalizing the Measurement
130
Status Reporting for Laser Wavelength Zeroing
132
Performing a User Wavelength Calibration
136
Measuring a Filter Response
137
Using Span to Zoom in on a Portion of the Response
139
Measuring the Bandwidth of a Filter
141
Measuring Insertion Loss of a Device
143
Measuring Insertion Loss and Return Loss Simultaneously
145
General Tips for Using Traces and Markers
148
Moving the Active Marker from One Trace to Another
149
Measuring the Delta between Two Traces
149
Optimizing the Sensitivity Setting
151
Creating a Limit Line to Establish Pass/Fail Criteria
155
Using Trace Math to Measure the Efficiency of the DUT
159
Using Trace Math to Measure Wavelength Drift
160
4 Remote Front Panel Operation
162
Remote Front Panel
163
Information and Equipment Required for the Configuration Process
163
Setting up the Analyzer for Remote Operation
165
Connecting to the Analyzer over the Network
167
Using the Reflection X Emulator to Run the Remote Front Panel
168
Using the X Win 32 Emulator to Run the Remote Front Panel
170
Using a UNIX Workstation to Run the Remote Front Panel
173
Using the Remote Front Panel
175
5 Remote Operation
176
Summary for Experienced GPIB Programmers
180
Introduction to Controlling an WDCA
186
SCPI Syntax Rules
189
Monitoring the Instrument
195
Normalizing the Measurement
200
WDCA Techniques to Improve Throughput
203
Example Programs
208
Example 1, Acquire Trace
209
Example 2, User Calibration
214
Example 3, Normalization
217
Example 4, Markers
223
Example 5, Zero Span
230
Example 6, Acquire Binary Trace
236
Example 7, VC++ Example
250
Example 8, Command Preset
252
Front Panel Functions to Remote Commands
256
6 Programming Commands
262
Command Conventions
264
Front Panel Functions to Remote Commands
265
Command Trees
271
Common Commands
277
Calculate Subsystem Commands
287
Calibration Subsystem Commands
327
Display Subsystem Commands
330
Format Subsystem Commands
334
Hcopy Subsystem Commands
335
Initiate Subsystem Commands
337
Memory Subsystem Commands
339
Mmemory Subsystem Commands
340
Output Subsystem Commands
343
Sense Subsystem Commands
344
Status Subsystem Commands
352
System Subsystem Commands
357
Trace Subsystem Commands
362
UNIT Subsystem Commands
368
Agilent 86140B Series Command Compatibility to Agilent 86082A Series
370
7 Status Listings Overview
379
Overview
379
Error Reporting Behavior
381
SCPI-Defined Errors
382
Standards Related Information
382
Standard SCPI Errors (-1 to -999)
383
Error/Event Numbers
383
Command Errors
383
Execution Errors
388
Device-Specific Errors
391
Query Errors
392
Amplifier, Source Test, and Normalization Errors
394
Analyzer Notices
395
Analyzer Warnings
396
Application-Specific Warnings
408
Analyzer Status Errors
414
Analyzer Errors
415
Firmware Errors
417
8 Maintenance Troubleshooting
419
Start-Up Process
419
Error Messages
419
Troubleshooting
419
Isolating Instrument Problems
420
Changing the Printer Paper
422
Printer Head Cleaning Procedure
424
Cleaning Connections for Accurate Measurements
428
Choosing the Right Connector
428
Inspecting Connectors
431
Cleaning Connectors
435
Care of Connector Savers
438
Cleaning Connector Savers
439
Returning the Instrument for Service
441
Preparing the Instrument for Shipping
443
Agilent Technologies Service Offices
445
Regulatory Information
446
9 Specifications and Regulatory Information
448
Definition of Terms
448
Specifications
451
Regulatory Information
451
Angled Connector Specifications
452
Wavelength Specifications
453
Amplitude Specifications
455
System and Other Specifications
457
General Instrument Specifications
458
Advertisement
Advertisement
Related Products
Agilent Technologies 86038B
Agilent Technologies 86038A
Agilent Technologies Agilent 86120B
Agilent Technologies 86120C
Agilent Technologies 86121A
Agilent Technologies 86141B
Agilent Technologies 86144B
Agilent Technologies 86146B
Agilent Technologies 8614 B Series
Agilent Technologies 86061C
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL