5. Repair Instructions:
Replace throttle position sensor. Refer to
2.2.7.21 DTC P0130 P0131 P0132 P0133 P0134 P2195 P2196
1. DTC Descriptor:
DTC
P0130
DTC
P0131
DTC
P0132
DTC
P0133
DTC
P0134
DTC
P2195
DTC
P2196
After the vehicle is started, the control module works in the open-loop mode and ignores pre-catalytic oxygen sensor signal voltage
when calculating air-fuel ratio. The control module provides approximately 450mV reference voltage to the pre-catalytic oxygen
sensor. When the engine starts running, the pre-catalytic oxygen sensor will be heated and begin to generate a 0-0.1 V voltage.
This voltage fluctuates. Once the control module detects that the pre-catalytic oxygen sensor voltage exceeds a threshold voltage,
it will immediately enter into the closed-loop mode. Control module determines the Air-Fuel ratio using the received pre-catalytic
oxygen sensor voltage signal. If the pre-catalytic oxygen sensor voltage increases to over the reference voltage (tend to 1 V), it
indicates that the air fuel mixture is too rich. If the pre-catalytic oxygen sensor voltage decreases to below the reference voltage
(tend to 0 mV), it indicates that the air fuel mixture is too lean.
ECM provides a signal through ECM harness connector EN01 terminal No.45 to pre-catalytic oxygen sensor wiring harness
connector EN02 terminal No.4; a low internal reference voltage through ECM harness connector EN01 terminal No.39 to Pre-
Catalytic oxygen sensor wiring harness connector EN02 terminal No.3.
2. Conditions For Setting DTC and The Fault Location:
DTC
DTC Detection Strategy
Code
1. Pre-Catalytic Oxygen Sensor
Voltage Too Low In an Extended
Period of Time
P0130
2. Short to Ground When Cold
3. Pre-Catalytic Oxygen Sensor
Voltage Leakage
2.2.8.3 Throttle Position Sensor
Pre-Catalytic Oxygen Sensor Signal Unreasonable
Pre-Catalytic Oxygen Sensor Circuit Voltage Too Low
Pre-Catalytic Oxygen Sensor Circuit Voltage Too High
Pre-Catalytic Oxygen Sensor Aging
Pre-Catalytic Oxygen Sensor Malfunction
Pre-Catalytic Oxygen Sensor Aging (Too Lean)
Pre-Catalytic Oxygen Sensor Aging (Too Rich)
Conditions For Setting The DTC (Control Strategy)
1. Pre-Catalytic oxygen sensor output voltage is
between 0.06-0.40 V.
2. Pre-Catalytic oxygen sensor output voltage is less
than 0.06 V.
3. Pre-Catalytic oxygen sensor output voltage is greater
than 0.611 V and less than 1.5 V and Post-Catalytic
oxygen sensor output voltage is 0.099 V.
Control System JL4G18-D
Replacement.
EC718/EC718RV EC715/EC715RV 10/2009
2-109
Fault Locations
1. Sensor Circuit
2. Sensor
3. ECM