2-34
Control System JL4G18-D
Datalink Connector IP12
16
15
14
8
7
6
Yes
Check datalink connector ground circuit.
Step 13
Datalink Connector IP12
16
15
14
8
7
6
Yes
Step 14
Is the engine running properly?
Yes
Step 15
Terminal continuity check.
EC718/EC718RV EC715/EC715RV 10/2009
13
12
11
9
10
5
4
3
2
1
FE02-5000b
13
12
11
9
10
5
4
3
2
1
FE02-5001b
(a)
Turn the ignition switch to "ON" position.
(b)
Measure the voltage between datalink connector IP12
terminal 16 and a reliable ground.
Standard Voltage: 11-14 V
Is the voltage normal?
Check if the circuit between terminal 16 and
No
the IF21 fuse open.
(a)
Turn the ignition switch to "OFF" position.
(b)
Measure the voltage between datalink connector IP12
terminal 4 and a reliable ground.
Standard Resistance: Less than 1 Ω
Check if the circuit between terminal 4 and the
No
ground open.
Engine immobilizer control module and ECM
No
communication failure, check and repair the
relevant components. Refer to
2.5.7.12 Engine Anti-theft Warning Lamp
Flashing, Vehicle Can Not Start
Engine