2-552
Starting / Charging System JL4G18-D
–
Because the generator wiring harness connector EN07
terminal No.3 and the battery is connected, when the
battery is fully charged, the regulator will reduce the
magnetic field excitation current, thereby reducing the
generator output voltage to prevent overcharging. When
the battery discharging or load is big, the voltage regulator
increases the magnetic field excitation current to increase
the generator output voltage.