Geely EC718 2009 Workshop Manual page 650

Table of Contents

Advertisement

2-568
Starting / Charging System JL4G18-D
Generator Harness Connector EN07
1
Yes
Replace the generator. Refer to
Step 7
Step 8
Are Instrument cluster, electric windows, air-conditioning system working properly?
Yes
The circuit between EN07 terminal No.2 and instrument cluster fuse IF25 is open. Check and repair the faulty
Step 9
part.
Next
Diagnostic completed.
Step 10
2.11.7.7 Charging Indicator Always Off
Step 1
Connect the ignition switch, and keep the engine off, is battery charging indicator on?
Yes
Step 2
Disconnect generator harness connector EN07, is battery charging indicator on?
Yes
Check the generator regulator power supply circuit.
Step 3
EC718/EC718RV EC715/EC715RV 10/2009
2
3
FE02-9411b
2.11.8.3 Generator
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Measure voltage between generator harness connector
EN07 terminal No.2 and a reliable ground.
Standard Voltage: 11-14 V
(d)
Connect generator harness connector EN07.
Is the voltage specified value?
Go to step 8
No
Replacement.
Relay IG1 does not provide IG1 power. Check
No
the IG1 relay.
Intermittent Fault. Refer to
No
Fault Check
Go to step 6
No
Refer to
2.11.7.6 Charging Indicator Always
Is the voltage specified value?
Engine
2.2.7.3 Intermittent
OnStep 4.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec715rv 2009Ec718rv 2009Ec715 2009