Engine
Pre-catalytic Oxygen Sensor
Yes
Check the terminal No.2 to ground voltage.
Step 3
Pre-catalytic Oxygen Sensor Harness Connector
4
Yes
Step 4
Check the Pre-Catalytic oxygen sensor terminal heating control signal continuity.
FE02-5009b
EN02
3
2
1
FE02-5010b
Control System JL4G18-D
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect oxygen sensor wiring harness connector.
(c)
Measure heater resistance between the Pre-Catalytic
oxygen sensor terminal No.1 and terminal No.2.
Standard Resistance: 9 Ω(68 ºF) at 20°C
(d)
Connect the Pre-Catalytic oxygen sensor wiring harness
connector.
Is resistance the specified value?
Replace the Pre-Catalytic oxygen sensor.
No
Refer to
Replacement
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect the Pre-Catalytic oxygen sensor wiring harness
connector.
(c)
Turn the ignition switch to "ON" position.
(d)
Measure the Pre-Catalytic oxygen sensor wiring harness
connector EN02 terminal No.1 to ground voltage.
Standard Voltage Value: Voltage between the EN02 terminal No.1
and the ground is 11-14 V.
(e)
Connect the Pre-Catalytic oxygen sensor wiring harness
connector.
Is voltage the specified values?
Pre-Catalytic Oxygen Sensor Power Supply
No
Circuit Fault
EC718/EC718RV EC715/EC715RV 10/2009
2.4.7.2 Pre-Catalytic Oxygen Sensor