Engine
DTC Code DTC Detection Strategy Conditions For Setting The DTC (Control Strategy)
1. Oxygen sensor signal
circuit open
P0140
2. Oxygen sensor high-
temperature and high
resistance
3. Schematic
12
From Battery
4. Diagnostic Steps:
Connect scan tool.
Step 1
Next
Step 2
Start engine and turn on the scan tool.
Next
Step 3
Select on the scan tool: Engine / read data flow / group 1 oxygen sensor voltage 2(Post-Catalytic oxygen
sensors).
1. Engine running longer than 60 s.
2. Coolant temperature is less than 70 °C (158 ºF).
3. Post-Catalytic oxygen sensor signal exceeds a
reasonable range.
4. Duration longer than 25 s.
Main Relay
Post-catalytic Oxygen Sensor
Control System JL4G15-D
D
C
B
A
EC718/EC718RV EC715/EC715RV 10/2009
2-681
Fault Locations
Engine
Control
Module
FE02-5206b