8400 StateLine C | Reference manual
Function library
System blocks | LS_ParFix
16.2.14

LS_ParFix

This system block outputs various fixed values (constants) to be used in the
interconnection.
Outputs
Identifier
bTrue
nPos100_a
nNeg100_a
nPos199_99_a
nNeg199_99_a
w65535
wDriveCtrl
864
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Value/meaning
Data type
1 ≡ TRUE
BOOL
16384 ≡ + 100 %
INT
-16384 ≡ - 100 %
INT
32767 ≡ + 199.99 %
INT
-32767 ≡ - 199.99 %
INT
65535 ≡ 0xFFFF
WORD
9 ≡ 0x0009
• Bit 0, SwitchOn = TRUE
WORD
• Bit 3, EnableOperation = TRUE
• All others: FALSE
See also:
wCANControl/wMCIControl control words ( 103)