L_Negation_1 - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8400 StateLine C | Reference manual
Function library
Function blocks | L_Negation_1
16.1.25

L_Negation_1

This FB converts the sign of the input signal, i.e. the input signal is multiplied by the value
-1 and is then output.
 With the value - 32768 at the nIn_a input, the value + 32767 is provided at the nOut_a
output.
Inputs
Identifier
nIn_a
Outputs
Identifier
nOut_a
814
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Value/meaning
Data type
Input signal
INT
Value/meaning
Data type
Output signal
INT