16.1.40

L_PT1_1

This FB filters and delays analog signals.
 The filter time constant T can be set under C00249.
 The gain is defined with V
Inputs
Identifier
nIn_a
Outputs
Identifier
nOut
Parameter
Parameter
C00249
Function
[16-22] Filter time constant T of the first-order delay element
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
= 1.
p
Information/possible settings
Data type
Input signal
INT
Value/meaning
Data type
Output signal
INT
Possible settings
0
ms
V = 1
p
T
L
8400 StateLine C | Reference manual
Function blocks | L_PT1_1
Info
5000 Filter time constant
• The filter is not active with a
setting of "0 ms". The input signal
is passed through one-to-one to
the output.
• Lenze setting: 2000 ms