16.1.29

L_NSet_1

This FB is used for general signal processing of process values and is provided with the
following functions:
 Ramp function generator
– With linear ramps for main and additional setpoint path
– With S-shaped ramp (PT1 rounding)
– Setting and holding
 Internal limitation of the input signal
 3 adjustable blocking zones
 Arithmetic function
 15 fixed setpoints (JOG setpoints)
 15 acceleration and deceleration times