8400 StateLine C | Reference manual
I/O terminals

User-defined terminal assignment

6.4
User-defined terminal assignment
In order to individually adapt the preconfigured assignment of the input/output terminals
to your application, you can choose one of the following procedures:
A. In the »Engineer«:
– Change the terminal assignment on the Terminal assignment tab.
– Change the signal assignment on the Application Parameters tab, on the dialog level
Overview  Signal flow.
– Change the interconnections in the FB editor (on the I/O level).
B. In the »Engineer« or with the keypad:
– Change the parameters for signal configuration in the parameters list.
Note!
If you change the preconfigured assignment of the input/output terminals, the
terminal assignment will be a user-defined one. In C00007, control mode "0:
Interconnection changed" will be shown.
Tip!
First of all, select a Lenze configuration useful for the purpose at hand by going to
C00005
then going to
have an application for which there is a signal flow, logical block links and terminal
assignment.
We recommend using the »Engineer« for the implementation of comprehensive
user-defined drive solutions.
282
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
and selecting a technology application that matches your drive task and
C00007
and selecting an appropriate control mode. You will then
L
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011