In comparison to the V/f characteristic control without feedback, the following can be
achieved by means of sensorless vector control SLVC:
 A higher maximum torque throughout the entire speed range
 A higher speed accuracy
 A higher concentricity factor
 A higher level of efficiency
 The implementation of torque-actuated operation with speed limitation
 The limitation of the maximum torque in motor and generator mode for speed-
actuated operation
5.7.1

Parameterisation dialog/signal flow

Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Go to Workspace and change to the Application parameters tab.
3. Select the motor control "4: SLVC: Vector control" from the Overview dialog level in
the Motor control list field (C00006):
4. Click the Motor control vector button to change to the Overview  Motor control
vector dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the >>More details button in the left-most position, a signal
flow with more details/parameters is displayed, as shown in the following
subchapter.
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8400 StateLine C | Reference manual
L
Motor control (MCTRL)
Sensorless vector control (SLVC)
161