8400 StateLine C | Reference manual
System bus "CAN on board"
Parameter data transfer
10.9.1
Identifiers of the parameter data objects
In the Lenze setting, the basic identifiers of the SDOs are preset according to the
"Predefined Connection Set".
The identifiers of the parameter data objects SDO1 and SDO2 result from the basic
identifier and the node address set under code C00350:
Identifier = basic identifier + node address
Object
SDO1
(Parameter data channel 1)
SDO2
(Parameter data channel 2)
Heartbeat
Boot-up
10.9.2
User data
Structure of the user data of the parameter data telegram
1st byte
Command
Note!
For the user data, the Motorola format is used.
Parameter data telegram examples
The following subchapters provide detailed information on user data.
458
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
from device
TSDO1
RSDO1
TSDO2
RSDO2
2nd byte
3rd byte
4th byte
Index
Subindex
LOW byte
HIGH
byte
L
Direction
Lenze-Base-ID
to device
dec
1408
1536
1472
1600
1792
1792
5th byte
6th byte
Data 1
Data 2
LOW word
LOW byte
HIGH byte
( 464)
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
CANopen-Base-ID
hex
dec
hex
580
1408
580
600
1536
600
5C0
1472
5C0
640
1600
640
700
1792
700
700
1792
700
7th byte
8th byte
Data 3
Data 4
HIGH word
LOW byte
HIGH byte

Hide quick links: