Parameterising The Motor Control - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

3.7.3

Parameterising the motor control

1. Go to Workspace and change to the Application parameters tab.
– The motor control parameters, among other things, can be found on the left:
2. In the
3. Adapt the motor control parameters:
Parameter
V/f base frequency
(C00015)
Imax in motor mode
(C00022)
Vmin boost
(C00016)
Related topics:
Notes on motor control
Motor control (MCTRL)
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Commissioning of the "Switch-off positioning" technology application
Motor control list field (C00006), select the desired motor control.
Lenze setting
Value Unit
50.0 Hz
47.00 A
1.60 %
( 49)
( 106)
L
8400 StateLine C | Reference manual
Info
Adapting the V/f base frequency ( 132)
Optimising the Imax controller ( 136)
Adapting the Vmin boost ( 134)
Commissioning
65

Hide quick links:

Advertisement

Table of Contents
loading