3.8

PC manual control

This function extension is available from version 06.00.00 and is supported by the
»Engineer« from version 2.13!
For test and demonstration purposes, PC manual control can be used to manually control
various drive functions via the »Engineer« when an online connection has been
established.
Supported drive functions:
 Speed control (follow a speed setpoint)
 Activate/Deactivate quick stop
Other control functions:
 Reset error message
 Set digital/analog outputs (in preparation)
Diagnostic functions:
 Display of the actual speed value and motor current (in a temporal characteristic)
 Display of the current device status
 Display of the status determining error
 Display of the status of the digital/analog inputs (in preparation)
3.8.1
Activating PC manual control
Stop!
PC manual control must be explicitly activated by the user.
If PC manual control is activated, the controller is inhibited via device command
(C00002/16) first.
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8400 StateLine C | Reference manual
L
Commissioning
PC manual control
69