Terminal Assignment Of The Control Modes - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

7.3.3

Terminal assignment of the control modes

The following comparison provides information about which inputs/outputs of the application block LA_SwitchPos are
interconnected to the digital and analog input/output terminals of the drive controller in the different control modes.
10:
Terminals 0
12:
Digital input terminals
X4/RFR
Controller enable
X4/DI1
Fixed setpoint 1/3
bJogCtrlJog1
X4/DI2
Fixed setpoint 2/3
Stop function 2
bJogCtrlJog2
bJogCtrlStop2
X4/DI3
Reset error message
bFailReset
X4/DI4
Change of direction of
rotation
bSetSpeedCcw
Analog input terminals
X3/A1U, A1I
10 V ≡ 100 % reference speed (C00011)
Digital output terminals
X4/DO1
-
X101/COM, NO
-
Analog output terminal
X3/O1U
-
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Terminals 2
14:
Terminals 11
16:
Terminal 16
Stop function 1
Fixed setpoint 1/3
bJogCtrlStop1
bJogCtrlJog1
Selection: Pre-switch off
Fixed setpoint 2/3
1
bJogCtrlJog2
bJogCtrlSlowDown 1
CW rotation quick stop
CW rotation quick stop
bRLQCw
bRLQCw
Selection: Switch-off position 1
bJogCtrlInputSel1
CCW rotation quick stop
CCW rotation quick stop
bRLQCcw
bRLQCcw
Selection: Switch-off position 2
bJogCtrlInputSel2
Main speed setpoint
nMainSetValue_a
-
-
-
-
-
-
Control mode (C00007)
20:
Keypad
21:
Controller enable / Reset of error message
bFailReset
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PC
30:
CAN
40:
MCI
Stop function 1
bJogCtrlStop1
Selection: Pre-switch off 1
bJogCtrlSlowDown 1
Stop function 2
bJogCtrlStop2
Selection: Pre-switch off 2
bJogCtrlSlowDown 2
Additional speed setpoint
nAuxSetValue_a
10 V ≡ 100 % reference speed (C00011)
-
-
-
-
-
-