L_Transient_2 - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8400 StateLine C | Reference manual
Function library
Function blocks | L_Transient_2
16.1.45

L_Transient_2

This FB serves to evaluate digital signal edges and convert them into timed, retriggerable
pulses. Rising signal edges, falling signal edges or both signal edges can be evaluated.
Inputs
Identifier
bIn
Outputs
Identifier
bOut
Parameter
Parameter
C01138/2
C01139/2
For a detailed functional description see L_Transient_1.
852
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Information/possible settings
Data type
Input for edge evaluation
• The function depends on the selection of edge evaluation in C01138/2.
BOOL
Value/meaning
Data type
Output (retriggerable)
BOOL
Possible settings
0 High edge
1 Low edge
2 High and low edge
0.001
L
Info
Function
• Selection of edge evaluation
Lenze setting
s
60.000 Pulse duration
• Lenze setting: 0.001 s
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011