16.1.29.2
JOG setpoints
In addition to the direct main setpoint selection via the nNSet_a input, so-called JOG
setpoints can be preset in C00039/1...15.
The JOG setpoints are binary-coded and can be called using the bJog1 ... bJog8 selection
inputs so that 15 options are available:
bJog8
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
The number of selection inputs to be assigned depends on the number of JOG setpoints
required:
Number of JOG setpoints required
1
2 ... 3
4 ... 7
8 ... 15
16.1.29.3
Setpoint inversion
The output signal of the JOG function is led via an inverter.
The sign of the setpoint changes if bNSetInv is set to TRUE.
16.1.29.4
Value range of the input signal
The value range of the input signal can be limited by using the following parameters:
C00635: MaxLimit (default setting: +199.99 %)
C00636: MinLimit (default setting: -199.99 %)
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8400 StateLine C | Reference manual
Selection inputs
bJog4
bJog2
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
Number of selection inputs to be assigned (bJog1 ... bJog8)
At least 1
at least 2
at least 3
4
L
Function library
Function blocks | L_NSet_1
Main setpoint
Main setpoint
bJog1
FALSE
nNset_a
TRUE
C00039/1
FALSE
C00039/2
TRUE
C00039/3
FALSE
C00039/4
TRUE
C00039/5
FALSE
C00039/6
TRUE
C00039/7
FALSE
C00039/8
TRUE
C00039/9
FALSE
C00039/10
TRUE
C00039/11
FALSE
C00039/12
TRUE
C00039/13
FALSE
C00039/14
TRUE
C00039/15
821