4.1.8

Device search function

This function extension is available from version 06.00.00!
In some applications where controllers are installed in control cabinets or are positioned in
a spacious plant, it is often difficult to locate a device connected online for e.g.
maintenance work. There is an established online connection with the device but you do
not know where the controller is located physically.
The
C00002/27
 For the time set in C00181/1, all four status LEDs at the front of the controller flash.
Afterwards, the function is turned off automatically.
 If the device command is executed again within the set time period, the duration is
extended accordingly.
 The setting
 Adjustable time period: 0 ... 6000 s (Lenze setting: 5 s)
Tip!
The device search function can also be activated via the
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
= "1: On / start" device command serves to carry out an "optical location":
C00002/27
= "0: Off / ready" serves to abort or switch off the function.
L
8400 StateLine C | Reference manual
Device commands (C00002/x)
Device control (DCTRL)
toolbar icon.