Using Di1 And Di2 As Frequency Inputs - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

6.1.1.2

Using DI1 and DI2 as frequency inputs

General information on using the input terminals as frequency inputs
The frequency inputs serve to detect HTL encoders with any number of increments and
single-track and two-track signals. Single-track signals can be evaluated with or without
rotation signal.
Note!
• Make sure that, when motor control with speed feedback is in use, the
maximum input frequency of the respective input terminal is not exceeded.
– DI1/DI2: f
• If the encoder signal is used as an actual speed value:
Number of encoder pulses / revolution
Example of DI1/DI2 (according to the previous note):
 Number of encoder increments: 512 pulses / motor revolution
 Reference speed (C00011): 1500 rpm
 Speed setpoint: 100 %
 Result: The speed or the number of increments is too high!
Tip!
From version
encoder position. Detailed information on this topic is provided in the
the encoder position of the DI1/DI2 frequency
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
= 10 kHz
max
1500 rpm
Input frequency
------------------------ -
=
60 s
06.00.00, the
L
8400 StateLine C | Reference manual
8192!
×
512 pulse
12800 pulse/s
=
LS_DigitalInput
system block can also provide the
input".
I/O terminals
Digital terminals
12.8 kHz
=
"Output of
( 268)