8400 StateLine C | Reference manual
Function library
Function blocks | L_OffsetGainP_1
16.1.32
L_OffsetGainP_1
This FB can add an offset to an analog input signal and amplify it afterwards. Preferably to
be interconnected directly after the analog input terminals.
The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow. Division is not remainder considered.
Offset and gain are selected via parameters.
The value provided at the nOut_a output is internally limited to ±199.99 %.
Inputs
Identifier
nIn_a
Outputs
Identifier
nOut_a
Parameter
Parameter
C00670
C00696
Function
830
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Information/possible settings
Data type
Input signal
INT
Value/meaning
Data type
Output signal
• Internal limitation to ±199.99 %
INT
Possible settings
-100.0000
-199.99
%
nOut_a
(
nIn_a
=
L
Info
100.0000 Gain factor
• High gain factor for further
processing of smallest input
signals.
• Please observe the difference
with regard to the gain factors of
other blocks in percent
(±199.99 % ≈ 2).
• Lenze setting: 1.0000
199.99 Offset
• Lenze setting: 0.00 %
Offset
) Gain factor
⋅
+
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011