6.1.1.3

Using DI1 as a counter input

General information on use as a counting input
The counting input is used for counting fast edges. A 32-bit counter counts from a
parameterisable starting value up to a parameterisable comparison value and then
outputs a corresponding status signal.
 Possible counting range: 0 ... 2
Note!
• The starting value must be have been set so that it is smaller than the
comparison value. Otherwise, the counter will be kept at the starting value
because the condition "Count value
• Observe the maximum input frequency of the input terminal:
– DI1: f
Function assignment 4: DI1=CountIn / DI2=In
Select this setting in
terminal DI2 remains configured as a "normal" digital input.
Short overview of parameters for the counting inputs:
Parameter
Counting input DI1
C00115/1
C00621/3
C00621/4
C02840/1
C02840/2
C02841/1
C00443/1
Highlighted in grey = display parameter
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
31
- 1 (0 ... 2147483647)
= 10 kHz
max
C00115
to configure input terminal DI1 as a counter input. Input
Info
Fct. DI 1/2 10kHz
LS_DigitalInput: bCountIn1_Reset
LS_DigitalInput: bCountIn1_LoadStartValue
CountIn1: Starting value
CountIn1: Comparison value
CountIn1: Counter content
DIx: Terminal level
L
8400 StateLine C | Reference manual
Comparison value" has been satisfied.
0: DI1=In1 / DI2=In2
0: Not connected
0: Not connected
I/O terminals
Digital terminals
Lenze setting
Value Unit
0 incr
65535 incr
- incr
-
263