8400 StateLine C | Reference manual
Function library
Function blocks | L_Transient_1
16.1.44.1
Function 0: Evaluate rising signal edges
Pulse duration
[16-24] Switching performance for function selection "0: High edge"
Functional sequence
1. A FALSE-TRUE edge at the bIn input sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE
unless another FALSE/TRUE edge has been set at the bIn input.
– If an additional FALSE-TRUE edge occurs at the bIn input, the pulse duration starts
again from the beginning, i.e. the bOut output can be retriggered.
16.1.44.2
Function 1: Evaluate falling signal edges
Pulse duration
[16-25] Switching performance for function selection "1: Low edge"
Functional sequence
1. A TRUE-FALSE edge at the bIn inputs sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE
unless another TRUE/FALSE edge has been set at the bIn input.
– If an additional TRUE-FALSE edge occurs at the bIn input, the pulse duration starts
again from the beginning, i.e. the bOut output can be retriggered.
850
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
bIn
TRUE
FALSE
bOut
TRUE
FALSE
bIn
TRUE
FALSE
bOut
TRUE
FALSE
L
t
t
t
t
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011