8400 StateLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control (VFCplus)
5.4.3.6

Defining a user-defined V/f characteristic

This function extension is only available from version 04.00.00!
For individual adaptation of the motor magnetisation to the actual application, the motor
control "10: VFCplus: V/f definable" with a freely definable characteristic can be selected in
C00006
as an alternative if the linear and quadratic characteristics are not suitable.
Note!
The V/f base frequency (C00015) and the V
influence if this motor control is chosen.
 The 11 grid points (voltage/frequency values) of the characteristic are stipulated by
means of the 11 subcodes of
– It is necessary to set all 11 grid points by means of corresponding subcodes.
– If fewer grid points (voltage/frequency values) are needed, this can be achieved
indirectly by ascribing the same voltage and frequency values to consecutive grid
points.
Example: C00967/3 = C00967/4 and C00968/3 = C00968/4
– The grid points can be specified in any sequence. Internally, they are automatically
ordered from the minimum to the maximum frequency value.
– Above the maximum and below the minimum frequency, the previous rise is
continued until the maximum output voltage.
 In the Lenze setting, the 11 grid points represent a linear characteristic.
– 3-phase devices: Output voltage 400 V at f = 50 Hz
– 1-phase devices: Output voltage 230 V at f = 50 Hz
P1
P1
V
400 V
f
-50 Hz
[5-7]
Freely definable characteristic (Lenze setting for 3-phase devices)
140
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
C00967
C00967/1
C00968/1
C00967/2
C00968/2
P2
C00967/3
C00968/3
P3
P4
P5
-50
-40
-30
-20
P2
P3
P4
320 V
240 V
160 V
-40 Hz
-30 Hz
-20 Hz
L
boost (C00016) no longer exert an
min
and C00968.
U [V]
400
320
240
160
P8
80
P7
P6
-10
0
10
20
P5
P6
P7
80 V
0 V
80 V
-10 Hz
0 Hz
10 Hz
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
C00967/11
C00968/11
P11
P10
P9
f [Hz]
30
40
50
P8
P9
P10
160 V
240 V
320 V
400 V
20 Hz
30 Hz
40 Hz
50 Hz
P11