5.5.2

Comparison of VFCplusEco - VFCplus

The following characteristics show the impact of the energy-saving V/f characteristic
control (VFCplusEco) compared to the standard V/f characteristic control (VFCplus).
 The characteristics were recorded with a standard asynchronous motor 2.2 kW with
energy efficiency class IE1 at speed = 600 rpm.
 scaled torque in [%]
 efficiency in [%]
 motor voltage in [V]
 power factor
 electrical power in [W]
[5-8]
Comparison of VFCplusEco - VFCplus
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011