Output Of The Encoder Position Of The Di1/Di2 Frequency Input - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8400 StateLine C | Reference manual
I/O terminals
Digital terminals
6.1.2.1

Output of the encoder position of the DI1/DI2 frequency input

This function extension is available from version 06.00.00!
The
LS_DigitalInput
providing the encoder position.
 The integrator can take max. ±32000 encoder revolutions.
 The starting position can be loaded via inputs.
 The internal function can be set via parameters.
 In addition to the encoder position, the "Overflow occurred/distance processed" status
signal is provided.
Inputs
Identifier
DIS code | data type
bPosIn12_Load
dnPosIn12_Set_p
Outputs
Identifier
DIS code | data type
dnPosIn12_p
bPosIn12_State
268
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
system block has been extended by the integrator function for
Information/possible settings
Load angle integrator with starting value and reset status signal
BOOL
TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and
bPosIn12_State is reset to FALSE.
Starting value for angle integrator
DINT
Value/meaning
Angle output signal
• 65536 [incr.] ≡ 1 encoder revolution
DINT
• Overflow is possible (display via bPosIn12_State)
Status signal "Overflow occurred/distance processed"
• Status signal can be reset via bPosIn12_Load.
BOOL
TRUE Overflow has occurred or distance is processed.