V/F Characteristic Control; Phone: 800.894.0412 - Fax: 888.723.4773 - Web: Www.clrwtr.com - Email: Info@Clrwtr.com - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8400 StateLine C | Reference manual
Motor control (MCTRL)
Defining current and speed limits
How to adapt the peak current limitation:
V/f characteristic control (VFCplus):
• Reduce the slip compensation with C00021.
V/f control (VFCplus + encoder):
• Reduce the slip limitation to twice the rated motor slip with C00971.
• Reduce the V
Sensorless vector control (SLVC):
• Reduce the slip compensation with C00021.
• Reduce the limitation of the torque in motor mode via nTorqueMotLimit_a
(C00728/1) and the limitation of the torque in generator mode via
nTorqueGenLimit_a (C00728/2).
124

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

boost in C00016.
min
L
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011

Hide quick links: