Device Overload Monitoring (Ixt) - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

5.12.1

Device overload monitoring (Ixt)

C00064/1...3
Parameter
C00064/1
C00064/2
C00064/3
Highlighted in grey = display parameter
 If the device utilisation reaches the switch-off threshold set in C00123:
– The error response set in
– The
"OC5: Ixt
– The bMctrlIxtOverload status output of the
set to TRUE.
 A setting of
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
displays the device utilisation (ixt) in [%] in different time intervals:
Info
Device utilisation (Ixt)
• Maximum value of pulse utilisation (C00064/2)
and permanent utilisation (C00064/3).
Device utilisation (Ixt) 15s
• Pulse utilisation over the last 15 seconds (only for loads >160 %).
Device utilisation (Ixt) 3 min
• Permanent utilisation over the last 3 minutes.
C00604
overload" error message will be entered into the logbook.
C00604
= "0: No Reaction" deactivates the monitoring.
L
8400 StateLine C | Reference manual
will be carried out (Lenze setting: "Warning").
LS_DeviceMonitor
Motor control (MCTRL)
Monitoring
system block will be
233