Configuring exception handling of the output terminals

This function extension is only available from version 04.00.00!
Exception handling for the analog and digital output terminals in the event of an error can
be set via decoupling configuration and decoupling values.
 Bit-coded selection of the events that activate disconnection is carried out in
for the analog output terminal.
 Bit-coded selection of the events that activate disconnection is carried out in
for the digital output terminal.
Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Finally, the following parameters define the value/status that the output terminals are to
have when they are decoupled:
Parameter
C00442/1
C00448
Related topics:
Configuring exception handling of the CAN PDOs
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Configuring exception handling of the output terminals
Event
SafeTorqueOff
ReadyToSwitchOn
SwitchedOn
Reserved
Trouble
Fault
Reserved
Reserved
Reserved
Fail CAN_Management
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Info
AOut1_U: Decoupling value
DigOut decoupling value
L
8400 StateLine C | Reference manual
( 455)
I/O terminals
C00441
C00447
Lenze setting
Value Unit
0.00 %
Bit coded
281