Analog Switch - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

8400 StateLine C | Reference manual
Technology applications
"GeneralPurpose" functions
7.4
"GeneralPurpose" functions
Each technology application provides different free logic and arithmetic functions, so-
called "GeneralPurpose" functions.
For the interconnection of these functions, the application block features inputs and
outputs on the I/O level, which are linked to the logic/arithmetic function.
Note!
In the Lenze setting, the connectors for the "GeneralPurpose" functions are
hidden in the function block editor.
• These connections can be shown via the Connector visibilities command in
the Context menu of the application block.
Tip!
The inputs of the "GeneralPurpose" functions can also be linked to other output
signals via the configuration parameters of the technology application.
On the other hand, the outputs of the "GeneralPurpose" functions can be selected
in the configuration parameters of other inputs.
Related topics:
User-defined terminal assignment
TA "Actuating drive
TA "Switch-off
7.4.1

Analog switch

This function switches between two analog input signals. The switch-over is controlled by
a boolean input signal.
[7-5]
GeneralPurpose function "Analog switch"
 For a detailed functional description see FB L_AnalogSwitch.
346
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
( 282)
speed":
Configuration parameters
positioning":
Configuration parameters
C00830/14
nGPAnalogSwitchIn1_a
C00830/15
nGPAnalogSwitchIn2_a
C00833/13
bGPAnalogSwitchSet
L
( 315)
( 343)
0
nGPAnalogSwitchOut_a
1
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents