9.10
System block "LS_SetError_1"
This system block is used for error handling within the application.
The application can trip up to four different user error messages with parameterisable
error IDs and error responses via the four boolean inputs.
If several inputs are set to TRUE at the same time, the input with the lowest number
will trip the error message.
Inputs
Identifier
bSetError1
bSetError2
bSetError3
bSetError4
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Information/possible settings
Data type
Input for tripping
"US01: User error
• Error subject number: 980
BOOL
• Error number:
(C00581/1
Input for tripping
"US02: User error
BOOL
• Error subject number: 981
• Error number:
(C00581/2
Input for tripping
"US03: User error
• Error subject number: 982
BOOL
• Error number:
(C00581/3
Input for tripping
"US04: User error
• Error subject number: 983
BOOL
• Error number:
(C00581/4
L
8400 StateLine C | Reference manual
Diagnostics & error management
System block "LS_SetError_1"
1"
x 0x0400000) + (980 x 0x10000) + (C00161/1)
2"
x 0x0400000) + (981 x 0x10000) + (C00161/2)
3"
x 0x0400000) + (982 x 0x10000) + (C00161/3)
4"
x 0x0400000) + (983 x 0x10000) + (C00161/4)
425