Adjusting Online And Offline Interconnection - Lenze 8400 StateLine C Reference Manual

L-force drives; e84avsc series;
Hide thumbs Also See for 8400 StateLine C:
Table of Contents

Advertisement

15.5

Adjusting online and offline interconnection

If the »Engineer« detects that online and offline interconnection differ from each other,
the Compare interconnection dialog box is displayed with various options for the
adjustment:
Tip!
The dialog box can also be opened via the
Button
Accepting the interconnection from
the device
Transferring the interconnection to
the device
Showing differences
Cancel
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
8400 StateLine C | Reference manual
Adjusting online and offline interconnection
symbol in the FB Editor toolbar.
Function
Add the interconnection in the device to the FB Editor. The interconnection
existing in the FB Editor will be overwritten by this action.
Transfer the offline interconnection which is currently not visible in the FB
Editor to the device. The interconnection existing in the device will be
overwritten by this action.
Showing differences between online and offline interconnection.
Close the Adjust interconnection dialog box without making an adjustment.