8400 StateLine C | Reference manual

Function library

Function blocks
16
Function library
16.1
Function blocks
This chapter describes the function blocks which are available for the controller in the FB
Editor.
The system blocks are described in the following chapter
Overview of function blocks available
Function block
L_Absolute_1
L_AddSub_1
L_AnalogSwitch_1
L_AnalogSwitch_2
L_AnalogSwitch_3
L_And_1
L_And_2
L_And_3
L_Arithmetik_1
L_Arithmetik_2
L_Compare_1
L_Compare_2
L_Compare_3
L_DFlipFlop_1
L_DigitalDelay_1
L_DigitalLogic_1
L_DigitalLogic_3
L_GainOffset_1
L_GainOffset_2
L_GainOffset_3
L_Interpolator_1
L_JogCtrlExtension_1
L_MPot_1
L_MulDiv_1
L_Negation_1
L_Not_1
L_Not_2
L_Not_3
L_NSet_1
L_OffsetGain_1
L_OffsetGain_2
772
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Runtime Function
2 μs
... converts a bipolar input signal into a unipolar output signal.
3 μs
... adds / subtracts analog input signals.
2 μs
... switches between two analog input signals.
2 μs
... ANDs three binary signals.
7 μs
... combines two analog signals arithmetically.
L_Arithmetik_2 is available from version 11.00.00.
5 μs
... compares two analog signals and can be used e.g. to implement a
trigger.
L_Compare_3 is available from version 11.00.00.
1 μs
... provides two stable states depending on the input signals.
2 μs
... delays binary signals.
2 μs
... provides a binary output signal which is generated by the logic
combination of three input signals.
L_DigitalLogic_3 is available from version 11.00.00.
3 μs
... can amplify an analog input signal and then add an offset to it.
• Gain and offset can be set via FB inputs.
5 μs
... can interpolate a position setpoint and/or an analog value e.g. to
compensate for larger bus transmission cycles or to continue signal
characteristics if data telegrams are missing.
5 μs
... can be connected upstream to the
implement a switch-off positioning at limit switch.
10 μs
... replaces a hardware motor potentiometer as setpoint source.
4 μs
... multiplies the analog input signal with a factor.
2 μs
... negates an analog input signal.
2 μs
... inverts a digital input signal.
50 μs
... contains a ramp generator with comprehensive parameterisation and
control options to condition a setpoint signal.
4 μs
... can add an offset to an analog input signal and amplify it afterwards.
• Offset and gain can be set via FB inputs.
L
"System
blocks".
L_NSet
ramp generator to
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011