16.1.20

L_GainOffset_3

This FB can amplify an analog input signal and then add an offset to it. Preferably to be
interconnected directly after the analog input terminals.
 The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow. Division is not remainder considered.
 Gain and offset are selected via FB inputs.
 The value provided at the nOut_a output is internally limited to ±199.99 %.
Inputs
Identifier
nIn_a
nGain_a
nOffset_a
Outputs
Identifier
nOut_a
Function
Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Information/possible settings
Data type
Input signal
• Scaling: 16384 ≡ 100 %
INT
Gain factor
• Scaling: 16384 ≡ 100 %
INT
• 199.99 % ≈2
Offset
• Scaling: 16384 ≡ 100 %
INT
Value/meaning
Data type
Output signal
• Internal limitation to ±199.99 %
INT
nOut_a
nIn_a Gain factor
(
=
L
8400 StateLine C | Reference manual
Function blocks | L_GainOffset_3
Offset
)
+
Function library
803