S0000 : Command was finished.
$
Comment
Smart Configure will not be executed when the chassis is in silent mode and
the blade is not supporting silent mode.
When you specify a non-primary server blade in SMP configuration, the
following message appears without executing the Smart Configure.
E0640 : <Blade %1$d> Command was canceled. Specified blade is not the
primary blade of SMP

bmc-reset blade

Command
bmc-reset blade [<blade_no>] [-h|-s|-sb] [-F]
Description
You can reset BMC in the following three methods.
Turning OFF and ON the sub power supply of server blades
Restarting BMC on server blades
Restarting BMC on a specific server blade
You can specify a restart method using a parameter, -h, -s, or -sb.
Turning OFF and ON the sub power supply of server blades
Specify -h to turn OFF and then ON a specified server blade sub power
supply. If the server blade power supply is ON at that time, it is forcibly
turned OFF. In SMP configuration, specify the primary server blade
number to power OFF all server blades and then ON in the configuration
one after another.
Restarting BMC on server blades
Specify -s to restart BMC on a specified server blade. In SMP
configuration, specify the primary server blade number to restart BMC on
all server blades in the configuration one after another.
Restarting BMC on a specific server blade
Specify -sb to restart BMC only on a specified server blade regardless of
whether the server blade is in SMP configuration or not.
When you do not specify any of -h, -s, and -sb, the behavior is the same as
when -h is specified.
Role
Server Blade