Parameters
<sw_no>
Slot number of the switch module in the server chassis
-e <sw_connect>
Type of connection to management interface
int: Connecting through the management module console
mgmt: Connecting the management LAN port directly
sw: Connecting to the switch module external port
-i <ip_addr>
IP address
-s <subnet_mask>
Subnet mask
-g <default_gateway>
Default gateway of module
-w <dgw_to_lansw>
Setting default gateway to LAN switch module
This setting is for keeping compatibility with management module
firmware A0125 or earlier.
-F
Executes the command without inquiry.
Show items
None
Message
None
Example
[Switch module 0 is connected to the management LAN network.]
$ set sw-module mgmt-lan 0 -e mgmt -i 192.168.0.10 -s
255.255.255.0 -g 192.168.0.1
Confirm? (y/[n]):y
I0052 : <Switch module 0> Setting was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
2-98
Range is from 0 to 3.
Only one module can be selected.
enable: Applies the default gateway to the LAN switch module.
disable: Not applies the default gateway to the LAN switch module.
CLI command
Hitachi Compute Blade 500 Series CLI Console User's Guide