Show Power Ps-Module - Hitachi Compute Blade 500 Series User Manual

Cli console user's guide
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Show items
None
Message
None
Example
[Not limit the power consumption of server blade no.0 by EPC.]
$ set power capping -b 0 -e enable
Confirm? (y/[n]):y
I0037 : <Blade 0> Setting was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
[Not limit the power consumption of server blade no.0 by APC.]
$ set power capping -b 0 -a enable
Confirm? (y/[n]):y
I0037 : <Blade 0> Setting was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
Comment
Do not disable EPC (Emergency power control value).
When you specify a non-primary server blade in SMP configuration, the
setting will not affect the non-primary server blade operation. The following
message appears to warn you.
W0031 : <Blade X> Set data is not used. Specified blade is not the primary
blade of SMP. (X: a specified server blade number)
You cannot make APC settings in DCMI mode.

show power ps-module

Command
show power ps-module
Description
Shows the setting of power supply.
Role
Chassis
2-200
CLI command
Hitachi Compute Blade 500 Series CLI Console User's Guide