Set Mgmt-Module Mgmt-V6 Address - Hitachi Compute Blade 500 Series User Manual

Cli console user's guide
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

DNS0 : fe80::200:87ff:feb2:c20
DNS1 : fe80::200:87ff:feb2:c21
DNS2 : -----
S0002 : Command succeeded.
S0000 : Command was finished.
$
[To set the management LAN for the management module and to display the
link local address (IPv6)]
$ show mgmt-module mgmt-v6 setting -ld
-- Management module management LAN setting (IPv6) --
-- IPv6 address setting --
Allocation
Status
IP address
Prefix len
Default gateway : fe80::200:87ff:feb2:c20
-- IPv6 address setting --
Allocation
IP Address
-- Link local address DAD setting --
Action DAD fails: not disabling IPv6 operation
-- IPv6 Operation --
IPv6 Operation
-- Management module DNS setting --
Priority
-- Management module DNS setting (IPv4) --
DNS0
DNS1
DNS2
-- Management module DNS setting (IPv6) --
DNS0
DNS1
DNS2
S0002 : Command succeeded.
S0000 : Command was finished.
$
Comment
None

set mgmt-module mgmt-v6 address

Command
set mgmt-module mgmt-v6 address -st <setting> [-i <ip_address>]
[-p <prefix_len>] [-gs <dgw_setting>] [-g <default_gateway>] [-F]
Description
Sets the management LAN (IPv6) for management modules.
You can set a static address. To set a static address, enter the following
items:
2-134
: Static address
: enable
: fe80::200:87ff:feb2:c24
: 64
: Link local address
: fe80::200:87ff:feb2:c29
: enable
: IPv4
: 10.20.30.40
: 0.0.0.0
: 0.0.0.0
: fe80::200:87ff:feb2:c20
: fe80::200:87ff:feb2:c21
: ::
CLI command
Hitachi Compute Blade 500 Series CLI Console User's Guide