alert : Notify alert of Failure or Warning.
information : Notify alert of Information..
Alert retry interval (sec)
The retry interval (sec) when failing to notify an alert.
Range is from 5 to 50.(sec)
Alert retry duration (min)
The retry duration (min) when failing to notify an alert.
Range is from 4 to 20.(min)
Message
None
Example
[Displays the setting of ServerConductor/Blade Server Manager.]
$ show bsm setting
-- BSM command port setting --
Port number
-- BSM server setting --
Server name
IP address
Alert port
Alert level
Alert retry interval (sec) : 30
Alert retry duration (min) : 20
-- BSM server setting --
Server name
IP address
Alert port
Alert level
Alert retry interval (sec) : 20
Alert retry duration (min) : 10
S0002 : Command succeeded.
S0000 : Command was finished.
$
Comment
None

set bsm command port

Command
set bsm command port -p <bsm_port>] [-F]
2-234
CLI command
Hitachi Compute Blade 500 Series CLI Console User's Guide
: 21001
: SERV1
: 192.168.0.30
: 20011
: all
: BSM001
: 192.168.1.19
: 20011
: alert