Set Blade Preconf - Hitachi Compute Blade 500 Series User Manual

Cli console user's guide
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

S0000 : Command was finished.
$
[Powers on the server blade 0 immediately when the power is supplied to the
server chassis.]
$ set blade ac-recovery 0 -a pon -w 0
Confirm? (y/[n]):y
I0040 : <Blade 0> AC recovery was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
[Remains to power off the server blade 1 when the power is supplied to the
server chassis.]
$ set blade ac-recovery 1 -a stay
Confirm? (y/[n]):y
I0040 : <Blade 1> AC recovery was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
[Returns to the state of the server blade that in the last time when power is
supplied to the server chassis]
$ set blade ac-recovery 2 -a last
Confirm? (y/[n]):y
I0040 : <Blade 2> AC recovery was completed.
S0002 : Command succeeded.
S0000 : Command was finished.
$
Comment
When you specify a non-primary server blade, the setting will not affect the
server blade operation. The following message appears to warn you.
W0031 : <Blade X> Set data is not used. Specified blade is not the primary
blade of SMP. (X: a server blade you specified)

set blade preconf

Command
set blade preconf [<blade_no>] [-n <n+m>] [-w <wwn_type>] [-m
<mac_type>] [-F]
Description
Edits the server blade configuration for Smart Configure.
In SMP configuration, when you specify the primary server blade, the Smart
configure setting for all server blades is changed. When you specify a non-
primary server blade, the setting is changed but will not affect the server
blade operation.