232
Screw the line card into the chassis by rotating the handles until the card is fully seated
6.
and the handles are vertical.
Bring the line card online:
7.
user@switch> request chassis fpc slot slot-number online
You can install the optional cable management kit after the card is installed.
Removing a QFX10000 Line Card on page 232
QFX10000-36Q Line Card on page 55
QFX10000-30C Line Card on page 61
QFX10000 line cards are field-replaceable units (FRUs) that can be installed in the line
card slots on the front of the chassis. The line cards are hot-insertable and hot-removable:
you can remove and replace them without powering off the switch or disrupting switch
functions. However, we recommend that you take them offline before removing them.
If you have the optional line-card cable management system, it is not necessary to remove
the cable management system before removing the line card.
Before you remove a line card from the switch chassis:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage. See
"Prevention of Electrostatic Discharge Damage" on page
If there are any optical cables, (including transceivers, direct-attach copper (DAC), or
DAC break-out) installed in the line card), remove them before you remove the line
card. See Removing a Transceiver from a QFX Series Device.
Ensure that you know how to handle and store the line card. See
Line Cards, Control Boards, and Switch Interface Boards" on page
Ensure that you have the following parts and tools available to remove a line card from
a QFX10000 chassis:
ESD grounding strap
An electrostatic bag or an antistatic mat
NOTE:
Placing a line card in an electrostatic bag might require a second
person to assist with sliding the line card into the bag.
Replacement line card or a cover panel to cover the empty slot