292
Table 66: Chassis Component Alarm Conditions on QFX10000 Modular
Models (continued)
Chassis
Component
Alarm Condition
Hot
Too many hot-swap
interrupts are occurring.
swapping
Power
A power supply has been
removed from the
supplies
chassis.
A power supply has a high
temperature.
A power supply input has
failed.
A power supply output
has failed.
A power supply has
failed.
AC and DC power
supplies are installed.
Inadequate number of
power supplies.
Alarm
Severity
Remedy
Major
Replace the failed components.
(red)
Minor
Install a power supply in the empty
(yellow)
slot.
Major
Replace the failed power supply.
(red)
Major
Check power supply input connection
(red)
and the power cord.
Major
Check power supply output
(red)
connection.
Major
Replace the failed power supply.
(red)
Major
Do not mix AC and DC power
(red)
supplies.
Major
Install an additional power supply.
(red)