CHAPTER 16

Replacing Cooling System Components

Installing a QFX10000 Fan Tray

Copyright © 2017, Juniper Networks, Inc.
Installing a QFX10000 Fan Tray on page 177
Removing a QFX10000 Fan Tray on page 180
Installing a QFX10000 Fan Tray Controller on page 185
Removing a QFX10000 Fan Tray Controller on page 187
The QFX10008 and QFX10016 chassis have two independent, field-replaceable fan trays.
Each fan tray is a hot-removable and hot-insertable field-replaceable unit (FRU); you
can remove and replace the fan tray while the switch is running without turning off power
to the switch or disrupting switching functions.
Before you begin to install a fan tray:
Ensure you understand how to prevent ESD damage. See
Discharge Damage" on page
Ensure that you have the following parts and tools available to install a fan tray in a
QFX10000:
Electrostatic discharge (ESD) grounding strap
A Phillips (+) screwdriver, number 1 or 2 (optional), for the captive screws
A replacement fan tray
CAUTION:
The fan tray can be removed and replaced while the switch is
operating. However, the fan tray must be replaced within three minutes of
removing the fan tray to prevent the chassis from overheating.