Verify that a licensed electrician has attached the cable lug (provided in the accessory
1.
kit) to the grounding cable.
Connect the other end of the grounding cable to a proper earth ground, such as the
2.
rack in which the switch is mounted.
Attach an ESD grounding strap to your bare wrist, and connect the strap to the ESD
3.
grounding point next to the earthing posts (see
Figure 67 on page
163).

Figure 66: ESD Point for the QFX10008

1— Grounding point

Figure 67: ESD Point for the QFX10016

1— Grounding point
Remove the two screws on the chassis using a Phillips screwdriver.
4.
Place the chassis grounding lug and cable over the PEM nuts with the cable connection
5.
pointing to the left. See
Chapter 13: Connecting the Switch to Power
Figure 66 on page 163
Figure 68 on page 164
and
and
Figure 69 on page
164.
163