Figure 119: Esd Point On Qfx10008 Chassis Rear - Juniper QFX10016 Hardware Manual

Hide thumbs Also See for QFX10016:
Table of Contents

Advertisement

QFX10016 Switch Hardware Guide
222
Electrostatic bag or antistatic mat
Electrostatic discharge (ESD) grounding strap
To remove a SIB (see
Figure 122 on page
Take the SIB offline using the
1.
NOTE:
If you suspect the SIB is faulty and want to ensure packets do not
flow through the SIB, power down the SIB instead of taking the SIB offline.
To power down the SIB, use the
command. To bring up a new SIB up in the slot, you must delete the old
configuration using the
command.
Place an electrostatic bag or an antistatic mat on a flat, stable surface.
2.
Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD
3.
point on the chassis. There is an ESD point located next to the protective earthing
terminal and below
PSU 5
and below
PSU_9
on the QFX10016 (see

Figure 119: ESD Point on QFX10008 Chassis Rear

1— ESD point
225):
request chassis sib slot slot number offline
set chassis sib power-off slot slot number
delete chassis sib power-off slot slot number
on the QFX10008 rear panel (see
Figure 120 on page
Copyright © 2017, Juniper Networks, Inc.
command.
Figure 119 on page
222)
223.

Advertisement

Table of Contents
loading

Table of Contents