CHAPTER 23

Removing the Switch

Powering Off a QFX10000

Copyright © 2017, Juniper Networks, Inc.
Powering Off a QFX10000 on page 261
Removing a QFX10016 From a 4-Post Rack Using a Mechanical Lift on page 263
NOTE:
Use the following procedure to power off a QFX10000.
Before you power off a QFX10000:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage. See
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you do not need to forward traffic through the switch.
Ensure that you have the following parts and tools available to power off the switch:
An ESD grounding strap
An external management device such as a PC
An RJ-45 to DB-9 rollover cable to connect the external management device to the
console port on one of the Control Boards
To power off a QFX10000:
Connect to the switch using one of the following methods:
1.
Connect a management device to the console (
following the instructions in Connecting a QFX Series Device to a Management
Console.
Connect a management device to one of the two management (
the control board by following the instructions in Connecting a QFX10000 to a
Network for Out-of-Band Management.
Shut down Junos OS from the external management device by issuing the
2.
system halt
operational mode CLI command. This command shuts down the switch
gracefully and preserves system state information. A message appears on the console,
confirming that the operating system has halted.
) port on a Control Board by
CON
MGMT
) ports on
request
327.
261