Table 66: Chassis Component Alarm Conditions On Qfx10000 Modular - Juniper QFX10016 Hardware Manual

Hide thumbs Also See for QFX10016:
Table of Contents

Advertisement

QFX10016 Switch Hardware Guide
Table 65: Alarm Terms and Definitions (continued)
Term
Definition
Alarm types
Alarms include the following types:
Chassis alarm—Predefined alarm triggered by a physical condition on the device such as a power supply
failure or excessive component temperature.
Interface alarm—Alarm you configure to alert you when an interface link is down. Applies to
fibre-channel
alarm for the link-down condition, or have the condition ignored.
System alarm—Predefined alarm that might be triggered by a missing rescue configuration, failure to
install a license for a licensed software feature, or high disk usage.
Related
Documentation
Chassis Alarm Messages on QFX10008 and QFX10016 Modular Chassis Switches
290
, and
management-ethernet
Chassis Alarm Messages on a QFX3008-I Interconnect Device
Chassis Alarm Messages on a QFX3500 Device
Interface Alarm Messages on page 293
show chassis alarms
show system alarms
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms
are preset and cannot be modified.
Chassis alarms on QFX10008 and QFX10016 modular chassis have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of
the conditions described in
immediate action.
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left
unchecked, might cause an interruption in service or degradation in performance. A
yellow alarm condition requires monitoring or maintenance.
Table 66 on page 290
describes the chassis alarm messages on QFX10000 modular
chassis switches.

Table 66: Chassis Component Alarm Conditions on QFX10000 Modular

Models
Chassis
Component
Alarm Condition
Control
A Control board has
failed.
board
A Control board has been
removed.
interfaces. You can configure a red (major) or yellow (minor)
Table 66 on page
290. A red alarm condition requires
Alarm
Severity
Remedy
Major
Replace the failed Control board.
(red)
Minor
Install a Control board in the empty
(yellow)
slot.
Copyright © 2017, Juniper Networks, Inc.
,