Juniper QFX10016 Hardware Manual page 315

Hide thumbs Also See for QFX10016:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Table 66: Chassis Component Alarm Conditions on QFX10000 Modular
Models (continued)
Chassis
Component
Alarm Condition
Line Cards
A line card is offline.
A line card has failed.
A line card has been
removed.
Fan trays
A fan tray has been
removed from the
chassis.
One fan in the chassis is
not spinning or is spinning
below required speed.
A fan is not receiving
power from the fan tray
controller.
Fan Tray
A fan tray controller has
failed.
Controller
One of the fan tray
controller in the chassis is
not receiving enough
power.
Switch
One of the SIB has failed.
Interface
Boards
(SIBs)
SATA SSD
The SSD has failed or
removed.
slot
Ethernet
The Ethernet
management interface on
the Control board is
down.
Chapter 26: Alarm Messages
Alarm
Severity
Remedy
Minor
Check the line card. Remove and
(yellow)
reinstall the line card. If this fails,
replace the failed card.
Major
Replace the failed line card.
(red)
Major
Install a line card in the empty slot.
(red)
Major
Install the missing fan tray.
(red)
Major
Replace the fan tray.
(red)
Major
Check and replace the failed fan tray
(red)
controller if required.
Minor
Check and replace the failed fan tray
(yellow)
controller if required.
Major
Check the power supply.
(red)
Minor
Check the below:
(yellow)
The SIB is not receiving power.
The fan tray controller is having a
power problem.
Major
Install the SSD.
(red)
Minor
Check the interface cable
(yellow)
connection.
Reboot the system.
If the alarm recurs, open a support
case using the Case Manager link
at
http://www.juniper.net/support/
or call 1-888-314-5822 (toll free,
US & Canada) or 1-408-745-9500
(from outside the United States).
291

Advertisement

Table of Contents
loading